Troubleshooting
Problems the simulator reports
Each problem names its step. What it means and what to do:
| It says | What to do |
|---|---|
| Step n is out of the arm's reach | Move the station closer, approach from the side, or use a bigger arm |
| A joint would have to turn past its limit | Turn it back the other way first, or rotate the other way round |
| Step n: the forearm and the CNC would touch, and I found no way round | Something is in the way. Raise the approach, move the station, or reorder the steps |
| There's no room left there | The station is full. Use another slot, swap the pallet, or ask for fewer layers |
| That weighs more than the arm's payload | It needs a forklift, two people or a bigger arm |
| That doesn't belong there | The station doesn't accept that part kind. Check the station's accepts in the cell |
| I won't stack anything on a fragile box | Move fragile parts last so they end on top |
| Load a billet into the CNC before running it | A machine cycle needs a part loaded |
| Name the signal first | Add the input or output to the cell, for example "add an input called door_closed" |
| A vacuum gripper could take it by the top | The fingers can't hold it that way. Approach from the side, or change the gripper |
A program with problems can be saved but never sent for approval.
The planner is unavailable
Kata plans only with its AI planner. If the planner is busy, unavailable or doesn't answer, the Studio says so and plans nothing; it never falls back to a guess. On the public demo, planning is rate-limited for anonymous visitors. Try again in a few minutes, or sign in.
Approving
- I can't send a program or start a run. Only owners and operators of the workspace can.
- We haven't heard back. Seventh Axis replies to every program within 10 minutes. If it's longer, tell us.
- The program was sent back. The reason is on the program's page. Fix it, simulate again and send it again.
- Sending is refused: the cell isn't validated. The cell needs a current safety validation signed off by Seventh Axis. If you edited the cell since, it needs validating again.
- Sending is refused: the program has problems. Fix them and save again.
Running
- The run expired. Nobody typed
STARTat the bridge PC within five minutes. Start the run again; the program stays approved. - The bridge refuses every run. It's running without a console, as a background service. Run it in a console at the cell.
- The bridge refuses the run as changed. The program's script, the robot or the signature didn't match. Start it again from Kata; never edit an approved program on the PC.
- The run faulted straight away. The controller wasn't in Normal or Reduced safety mode. Clear the stop on the pendant first.
- Stop didn't reach the robot. The network, the bridge PC or the controller's network service failed. Use the e-stop: the app's Stop isn't one.
Pairing
- The code doesn't work. Codes work once and expire after 15 minutes. Create a new one.
- The bridge can't reach the robot. Check the controller's address on the Robots page, that remote control is enabled, and that the controller accepts connections from the bridge PC. See Network.
Still stuck? Get in touch.