Safety
This page is for the factory engineer or integrator installing Kata on a Universal Robots cell. It says what Kata does, what it doesn't, and what you must still do yourself.
Kata is not certified, and nothing in Kata makes a cell compliant or safe on its own. Under ISO 10218-2 the integrated cell is assessed: the integrator's risk assessment (ISO 12100), safety-rated hardware, the controller's safety configuration and validation on site. In Malaysia this sits under the Occupational Safety and Health Act 1994 (as amended in 2022) and DOSH's requirements.
Kata is not a safety function. It doesn't replace emergency stops, guards, interlocks, light curtains, scanners, enabling devices or the controller's safety configuration.
Before any run on a real cell
- A risk assessment for the whole cell (ISO 12100), kept on file, including foreseeable misuse and maintenance.
- Emergency stops fitted, wired to the controller's safety I/O and tested (ISO 13850, IEC 60204-1).
- Safeguarding fitted and tested: interlocked fences, scanners or light curtains, or a collaborative setup assessed to ISO/TS 15066.
- Safety-related control parts meet the performance level the risk assessment requires (ISO 13849-1).
- The controller's safety configuration is set and checked, and its checksum recorded.
- Safety distances calculated (ISO 13855) and checked on the floor.
- The cell's safeguarding mode in Kata matches the real cell.
- The bridge PC is at the cell with a clear view of the robot.
- A start button wired at the cell, if the risk assessment calls for one. Kata's start confirmation doesn't replace it.
- Controller and bridge on a protected network. See Network.
- Operators trained, and they know Kata's Stop is not an emergency stop.
- The cell's safety validation record filled in and signed off by Seventh Axis.
From plan to motion
Each gate catches something and misses something.
| Gate | Catches | Doesn't catch |
|---|---|---|
| Plan and simulation | Moves the arm can't make, collisions with what the cell model knows, overweight parts | Anything not in the cell model, such as a person |
| A clean simulation | A program saved with known problems | Problems the simulator can't see |
| Cell safety validation, signed off by Seventh Axis | A cell nobody reviewed, or one edited since sign-off | A change to the controller's safety configuration; a poor risk assessment |
| Seventh Axis approval of the program | A program nobody outside the cell has reviewed, or one edited since | — |
| The right role | A run started by someone who isn't an owner or operator | — |
| A signed, single-use, five-minute run | An edited program, the wrong robot, a replayed or stale run | — |
| The bridge re-checks everything | A tampered database row, a server fault | A compromised bridge PC |
START typed at the bridge PC |
A run started remotely with nobody at the cell | A confirmer who can't see the robot |
| Force and part checks in the program | A missing part or unexpected force | Anything the flange sensor can't feel |
| The controller's own safety system | — | This is the layer that protects people |
The start confirmation is a software confirmation on a PC. It's weaker than a start button wired at the cell, and your integrator may require one.
Safety validation record
Each cell has a record: the risk-assessment reference, the safeguarding mode, the controller's safety-configuration checksum read from the pendant, who validated it and the date. A workspace owner records it; Seventh Axis signs it off with a second factor before any run on that cell on a real robot. Seventh Axis also approves every program before it can run; see Approving and running.
The sign-off is tied to the cell as submitted: edit the cell and it must be validated again. Kata can't yet read the controller's live safety configuration, so record a new validation after any change to it. The sign-off is a gate in Kata's workflow, not a certification.
Scanner cells
For scanner cells Kata sizes the protective-stop field with ISO 13855's formula for a horizontal field, S = 1600 mm/s × T + (1200 − 0.4 × H, at least 850 mm), from the arm's reach plus its tool. T is the robot's stopping time plus the scanner's response time; H is the scanning plane's height. Enter your own figures in the cell editor; until you do, Kata uses stated assumptions (500 ms, 80 ms, 300 mm) and says so. It's a design aid: measure the real stopping performance on site.
When something goes wrong
- A safety stop or fault on the controller ends the run. Clear it on the pendant, then start a new run.
- A failed force or part check stops the program on a real arm, with a message on the pendant.
- Stop in the app sends a controlled program stop. It isn't an emergency stop.
- Network lost: a program already on the controller keeps running. Use the e-stop. Design the cell's safeguarding assuming Kata may be unreachable at any time.
- Run expired: nobody confirmed within five minutes. Start the run again.
- Cell edited after sign-off: runs are refused until it's validated again.
Reporting a safety issue
If you find a way Kata could move a robot when it shouldn't, skip a gate, or mislead an operator about safety, email seventhaxisrobots@gmail.com straight away and stop using the affected cell until you hear back. Include what you saw, the robot model and controller software version, and whether it was a real arm or URSim. Please don't post it publicly before we've fixed it.