# Network

The UR controller's network ports have **no authentication by design**: anything that can reach them can send the robot a program. The bridge needs some of those ports, and so would an attacker on the same network. The aim is that only the bridge PC can reach them.

This is guidance, not a certification. The integrator designs, builds and tests the network as part of the cell.

## Zones and conduits

IEC 62443-3-3 groups the assets that share a security need into a zone and controls every path in and out. For a Kata cell:

- **The cell zone:** the controller and the bridge PC.
- **One conduit out:** the bridge PC to the internet, outbound HTTPS only.
- **Everything else** on the plant network is outside the zone, with no path in.

## Layout

1. Put the controller and the bridge PC on **their own segment or VLAN**, separate from office and plant networks. A small managed switch or a second network card on the bridge PC is enough.
2. Give both fixed addresses.
3. Don't connect the controller to the plant network or give it a route to the internet.
4. No port forwarding to the controller or the bridge PC, from anywhere.

## Limit the controller to the bridge PC

In the controller's security settings, accept connections on ports **29999, 30001, 30002 and 30004 only from the bridge PC's address**. If you can't filter on the controller, filter on the switch or a firewall in front of it. Block the controller's other ports unless you need them.

## Outbound only

The bridge PC needs outbound HTTPS (port 443) to your Kata workspace's database and to the Kata site, `kata-seventh-axis.vercel.app`. Allow those and block the rest if you can. It needs **no inbound connections**: the bridge opens the connection out. Don't expose remote desktop or file sharing on the bridge PC.

## Keep the bridge PC in shape

- Install operating system and security updates.
- Run the bridge as a normal user, not an administrator.
- Strong password and a screen lock.
- Don't use it for browsing, email or other software.
- Keep removable media off it, or controlled.

## Check it

- [ ] The bridge PC is at the cell and sees the robot.
- [ ] Controller and bridge PC are on their own segment or VLAN.
- [ ] From another PC on the plant network, ports 29999, 30001, 30002 and 30004 on the controller don't answer.
- [ ] From the bridge PC they do.
- [ ] The bridge PC can make outbound HTTPS connections, and nothing can connect in.
- [ ] The bridge runs as a non-admin user, and the PC is patched.
- [ ] You know how to [unpair it](/docs/bridge).